User's Manual

WLS Installation and Maintenance Manual Installation
Geometrix
®
Wireless Location System 33
Andrew Corporation Proprietary
The AOA Calibration Test will only run on AOA WLS sites. The test automatically determines if a
WLS is AOA capable and which sectors are configured for AOA. It also determines the frequency
band(s) being filtered by the RFDU from the BPU initialization file. On each AOA sector, the
calibration signal level is measured on all four channels in the cellular A and B frequency bands
and in the PCS band.
To pass the test, the received signal level must be greater than a minimum threshold of -70 dBm
and the signal power of channels 2 through 4 must be within 5dB of channel 1, the reference
channel. The test is only required to pass in the frequency bands being passed by the RFDU.
Note: The AOA Calibration test results are only valid after all AOA antenna cables are
connected to the WLS and RFDU/antenna switch hardware.
An example of the test display for a WLS configured with one AOA sector and a PCS RFDU is
shown below.
Enter your choice: 7
AOA CALIBRATION TEST:
Sector 1 AOA Capable
Sector 2 Not AOA Capable
Sector 3 Not AOA Capable
Sector 4 Not AOA Capable
Cal signals in all required bands must be > -70.000000 dBm
Testing Cellular A Band:
Frequency: 830.000 MHz
Cal Signal Sector 1 / Chan 0 / Chan RSSI: -103.96 dBm --> low signal
Cal Signal Sector 1 / Chan 1 / Chan RSSI: -104.61 dBm --> low signal
Cal Signal Sector 1 / Chan 2 / Chan RSSI: -105.32 dBm --> low signal
Cal Signal Sector 1 / Chan 3 / Chan RSSI: -104.63 dBm --> low signal
Test Result: FAIL
Testing Cellular B Band:
Frequency: 840.000 MHz
Cal Signal Sector 1 / Chan 0 / Chan RSSI: -104.22 dBm --> low signal
Cal Signal Sector 1 / Chan 1 / Chan RSSI: -104.55 dBm --> low signal
Cal Signal Sector 1 / Chan 2 / Chan RSSI: -113.65 dBm --> low signal
Cal Signal Sector 1 / Chan 3 / Chan RSSI: -105.34 dBm --> low signal
Test Result: FAIL
Testing PCS A Band:
Frequency: 1856.040 MHz
Cal Signal Sector 1 / Chan 0 / Chan RSSI: -39.95 dBm
Cal Signal Sector 1 / Chan 1 / Chan RSSI: -40.71 dBm
Cal Signal Sector 1 / Chan 2 / Chan RSSI: -39.96 dBm
Cal Signal Sector 1 / Chan 3 / Chan RSSI: -40.37 dBm
Test Result: PASS
Calibration Test Results
Band Pass? Required?
Cell_A NO NO
Cell_B NO NO
PCS YES YES
Test Result: PASS