12) Read Serial/Model Numbers
Enter your choice:
Enter 1 to execute tests 2) through 6). This will begin a series of five subsystem tests. Each will
print the test title and a PASS/FAIL indicator after completion. All tests should show a PASS
indication. If any do not, a more detailed diagnostic can be run on the failed subsystem using the
applicable menu item.
The more detailed diagnostic will provide detailed information (e.g. cable open, no GPS signal,
etc.) to aid in troubleshooting. An example of the test display is shown below.
Enter your choice: 1
BPU/RX TEST:
BPU0
BUST: Host Register passed
BUST: EEP Conf Read passed
BUST: CPLD Load passed
BUST: HAP Default passed
BUST: P2S ID Read passed
BUST: Host ISA Timeout passed
BUST: SHARC Broadcast Load passed
BUST: Host SRAM Bank 0 passed
BUST: Host SRAM Bank 1 passed
BUST: Host Count Sharcs passed
BUST: SHARC Single Load passed
BUST: SHARC MP Access passed
BUST: Host DMA passed
BUST: SHARC Ping passed
BUST: SHARC SRAM passed
BUST: Semaphore test passed
BUST: SHARC to Host interrupt passed
BUST: UART serial test passed
BUST: Receiver intr test skipped
BUST: Receiver test skipped
BUST: PDC test passed
BUST: P2S test skipped
BUST: Link Port test passed
BUST: RTC test passed
BUST: TT continuous mode skipped
BUST: TT triggered mode passed
BUST: 5-wire bus test passed
BUST: ADC threshold test passed
BUST: Set defaults passed
Re-initializing ...
unzip_mcs_files has finished.
BPU/RX Test Result: PASS
BACKPLANE STATUS TEST:
Test Result: PASS
NOISE CORRELATION/POWER TEST:
Test Result: PASS
MEZZANINE TEST:
BPU 0: Testing SDRAM ...
Passed
BPU 0: Testing Secondary Mode...
Passed