ADVANCED/DELUXE ONE STEP AUTO-INFLATION Blood Pressure Monitor Trilingual Instruction Guide – MODEL UA-767 Plus English • Français • Español
✓ THIS MONITOR IS CLINICALLY VALIDATED This LifeSource® blood pressure monitor has undergone and passed a Clinical Validation study to determine the performance and accuracy. This monitor is clinically validated according to the British Hypertension Society (BHS) standard. The BHS is the most prestigious international blood pressure organization. The published study was performed by a reviewing committee consisting of physicians and/or nurses.
TABLE OF CONTENTS Fast. Easy. Accurate. Congratulations on purchasing a state-of-the-art LifeSource® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.
? MONITOR COMPONENTS WHAT DISPLAY SYMBOLS MEAN 1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7 Condition/Cause Recommended Action 1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7 Display Symbol 123 123 123 The symbol shown while meaMeasurement is in progress, surement is in progress. It blinks remain as still as possible. 123 while detecting the pulse. 123 1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7 An irregular heartbeat or body Take measurement again and 123 err CUf movement may have occurred.
? SELECTING THE CORRECT CUFF SIZE HOW UA-767 PLUS WORKS LifeSource® blood pressure monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” – a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
TAKING YOUR BLOOD PRESSURE TAKING YOUR BLOOD PRESSURE Tips for Blood Pressure Monitoring: ☞ Relax for about 5 minutes before measurement. ☞ Do not smoke or ingest caffeine at least 30 minutes prior to measurement. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Unless your physician recommends otherwise, use left arm to measure pressure. ☞ Do not talk during measurement. ☞ Do not cross legs and keep you feet flat on floor during measurement. 5. Press the START button.
WHAT IS AN IRREGULAR HEARTBEAT ABOUT AVERAGE READING 1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7 123 Blood Pressure Monitor provides a blood pressure and The UA-767 Plus 123 pulse rate measurement even when an irregular heartbeat occurs. The 123 Irregular Heartbeat will appear in the display window in the 123 symbol 123 Heartbeat has occured during measurement.
ABOUT MEMORY This monitor automatically stores up to thirty (30) blood pressure and pulse measurements in memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. The oldest reading displays as "n01". The M symbol in the upper left corner of the display screen indicates that you are viewing a previous measurement stored in memory. To retrieve readings, follow these simple steps: 1.
ABOUT BLOOD PRESSURE What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). What Affects Blood Pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season. Certain activities can significantly alter one’s blood pressure.
ABOUT BLOOD PRESSURE What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hypertension is treatable when diagnosed early.
TROUBLESHOOTING ABOUT BLOOD PRESSURE Establishing Baseline Measurements The most important method to get an accurate blood pressure measurement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of measurements that you can use to compare against future readings. To build this baseline measurement, devote two weeks for consistent blood pressure monitoring.
CONTACT INFORMATION SPECIFICATIONS Model . . . . . . . . . . . . . . . . . . . . . . . . . UA-767P (UA-767 Plus) Type. . . . . . . . . . . . . . . . . . . . . . . . . . . Oscillometric Display . . . . . . . . . . . . . . . . . . . . . . . . Digital character height Pressure (16.0 mm)/pulse (10.0 mm) displayed simultaneously Memory . . . . . . . . . . . . . . . . . . . . . . . 30 readings Measurement range . . . . . . . . . . .
IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free Auto Control Medical 1-800-461-0991 - In Canada A specially trained representative will assist you. A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com Pressure Rating Indicator is a trademark and LifeSource is a registered trademark of A&D Medical.