User Manual and Installation Instructions
— 9 —
 Important Safety Information
INSTALLATION WARNINGS
  To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the 
materials used will not discolor, delaminate or sustain 
other damage. 
 MOBILE HOME – ADDITIONAL INSTALLATION   
 REQUIREMENTS: 
  The installation of this appliance must conform to the 
Manufactured Home Construction and Safety Standard, 
Title 24 CFR, Part 3280 (formerly the Federal Standard 
for Mobile Home Construction and Safety, Title 24, HUD 
Part 280). 
  When such standard is not applicable, use the Standard 
for Manufactured Home Installations, ANSI A225.1/NFPA 
501A, ANSI A119.2.2–1982, or with local codes.
  In Canada, the installation of this range must conform 
with the current standards CAN/CSA-A240-latest 
edition, CAN/CGA Z240.4.2, or with local codes.
  MOBILE HOME INSTALLATIONS REQUIRE:
  When this range is installed in a mobile home, it must 
be secured to the oor during transit. Any method of 
securing the range is adequate as long as it conforms to 
the standards listed above.
  The installation of appliances designed for recreational 
park trailers must conform with state or other codes 
or, in the absence of such codes, with the standard for 
recreational park trailers, ANSI A119.5.
GAS DANGER
Explosion hazard conditions will exist unless 
you perform ALL of the following:
• UseanewCSAInternationalapprovedgas
supply line.
• Installashut-offvalve.
• Securelytightenallgasconnections.
• IfconnectedtoLP,haveaqualiedpersonmakesure
gas pressure does not exceed 10” (25 cm) (range 
tops)/14” (36 cm) (ranges) water column.
• Examplesofaqualiedpersoninclude:
  - Licensed heating personnel
  - Authorized gas company personnel
  - Authorized service personnel
  Failure to do so can result in death, explosion, or re.
• Observeallgoverningcodesandordinances.
  IMPORTANT: This installation must conform with all 
local codes and ordinances. In the absence of local 
codes, installation must conform with American National 
Standard, National Fuel Gas Code ANSI Z223.1 / NFPA 
54. - latest edition, or CAN/CGA B149 - latest edition. In 
Canada, installation must conform to the current natural 
Gas Installation /code, CAN 1-1.1-M81 and with local 
codes where applicable. This appliance has been design-
certied according to ANSI Z21.1b-201 latest edition. 
A statement of the maximum gas supply pressure in 
accordance with the inlet pressure rating of the gas 
appliance pressure regulator supplied.
 IMPORTANT: Leak testing of the appliance must be 
conductedaccordingtothemanufacturer’sinstructions.
• Theapplianceshouldbeconnectedtothesupplyline
with 1/2-inch black iron pipe or a certied exible type 
stove connector. To prevent gas leaks, put an approved 
sealing compound which is resistant to liqueed 
petroleum gases on all threaded connections.
• Gassupply should be located near the opening for this 
appliance (see Figure 2, ranges only):
Types of Gas
NATURAL GAS:
• ThisapplianceisdesignedforusewithNaturalgasor,
after proper conversion, for use with LP gas.
• ThisapplianceisfactorysetforusewithNaturalgas.The
model/serial rating plate has information on the types 
of gas that can be used. If the types of gas listed do not 
include the type of gas available, check with the local 
gas supplier.
LP GAS CONVERSION:
•
Conversion must be done by a qualied service technician.
• Noattemptshallbemadetoconverttheappliancefrom
the gas specied on the model/serial rating plate for 
use with a different gas without consulting the serving 
gas supplier.
2”
4”
10.5”
2”
6.25”
Figure 2
Area allows for 
ush installation 
with through-the-
wall connection 
of pipe stub / 
shut-off valve 
and rear wall 
120V outlet.
Area allows for ush installation 
with through-the-oor connection 
of pipe stub / shut-off valve.
Shortest connection 
from hard pipe stub 
location to range 
hook-up.