Use and Care Manual
IMPORTANT:
Observe all governing codes and ordinances.
It is the customer’s responsibility to contact a qualified electrical installer.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine
that the ground path is adequate.
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both
sides of the line.
DO NOT ground to a gas pipe.
Check  with  a  qualified  electrician  if  you  are  not  sure  that  the  range  hood  is  properly  grounded. 
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range  hood should  be connected  directly to  the fused  disconnect (or  circuit breaker)  box through
flexible  armored  or  non-metallic  sheathed  copper  cable.  UL/CSA  listed  strain  relief  must  be  provided  at
each end of the power supply cable.
ELECTRICAL REQUIREMENTS: