Installations (refer to Page 4 for parts):
NOTE: Use threaded drywall anchors only when
 mounting the hood on sheet rock. Mounting
 the hood on wall studs or lumbars is highly
 recommended.
Step 1: Measuring
• Measure the distance between stove top and the bottom of range hood. A distance of 24” to 30” is
 recommended with a minimum of 30” for gas stove tops.
Step 2: Preparing the cabinet
•
Measure and cut an opening at the bottom of the cabinet to fit the motor box of the range hood. (See Fig #1)
•
Measure and cut a hole in the top of cabinet to fit the duct tube. (See Fig #1)
Note that the hole in the top of the cabinet may not be necessary depending on venting method chosen.
(See Page 7)
Step 3: Attaching damper flap
•
Fix the damper flap into the damper hole on top of the range hood motor box. (See Fig #2)
INSTALLATION:
Hardware Note: For safety reasons, range hood mounting screws and anchors will not be 
included due to the variation of cabinetry constructions and wall material. Please consult your 
installation specialist regarding the optimal type of mounting screws and wall anchors to suit 
your home’s construction.
•