Installation Guide
1-888-686-0778
1) If  the  range  hood  or  halogen  light  does  not
operate after installation:
2) The range hood vibrates when the blower is on:
3) The blower or fan seems weak:
4) The  lights work but  the  fan  is not spinning  at
all, is stuck or is rattling:
5) The hood is not venting out properly:
TROUBLE SHOOTING:
• Check if the range hood has been plugged in,
make sure that all power has been turned back
ON,fused not blown and all electrical wiring
are properly connected.
• The range hood might not have been secured
properly on to the ceiling or wall.
•
Check  that  the  duct  sized  used  is  at  least  6”.
Range  hood WILL  NOT  function  efficiently
with insufficient duct size.  For example: 7”
duct over 6” hole and loosely secured.
• Check if duct  is clogged  or if damper  unit
(half-circular flange) is not installed correctly
or opening properly.  A tight mesh on a side
wall cap unit might also cause restriction to the
air flow.
•
The fan might be jammed or scraping the
bottom due to shipping damage. Please
contact us immediatelyDW
• Make sure the distance between the stove top
and the bottom of the hood is within 24” and
30”  in distance;  with  minimum  30”  for  gas
stove top.
• Reduce  the  number  of  elbows  and  length  of
duct work.  Check  if  all joints  are  properly
connected, sealed, and taped.