IMPORTANT: Observe all governing codes and
ordinances.
It is the customer’s responsibility:
Ŗ To contact a qual
iſed electrical installer.
If codes permit and a separate ground wire is used, it is recommended that a qualiſed electrician dete
rmine that
the ground path is adequate.
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides
of the line.
DO NOT ground to a gas pipe.
Check with a qualiſed electrician if you are not sure that the range hood is properly grounded.
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through ƀexible
armored or non-metallic sheathed copper cable. ETL : listed strain relief must be provided at each
end of the power supply cable.
Electrical Requirements :
end of the
power supply cable.