Installation Guide
Page 14
1.
If the range hood or LED light does not operate Ŗ Check if the range hood has been plugged in, make
sure that all power has been turned back ON, fused
not blown and all electrical wiring are properly con-
nected.
Swap out light assembly to working ones to deter-
mine whether it is caused by defective bulbs. See
Replacing the Light Bulbs on Page 22.
2. The range hood vibrates when the blower is on: Ŗ The range hood might not have been secured prop-
erly on to the ceiling or wall.
3. The blower or fan seems weak: Ŗ Check that the duct sized used is at least 7” or 3-1/4
x 10”. Range hood WILL NOT function efſciently
with insufſcient duct size. For example: 8” duct
over 7” hole and loosely secured.
Ŗ Check if duct is clogged or if damper unit (half-cir-
cular ƀapper) is not installed correctly or opening
properly. A tight mesh on a side wall cap unit might
also cause restriction to the air ƀow.
4. The lights work but the blower is not spinning at all, Ŗ
is stuck or is rattling.
The blower might be jammed or scraping the bot-
tom due to shipping damage. Please contact us im-
mediately.
5. The hood is not venting out properly: Ŗ Make sure the distance between the stove top and
the bottom of the hood is within 24” and 30” in
distance; with minimum 30” for gas stove top.
Ŗ Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
Ŗ Make sure the power is on high speed for heavy
cooking.
after installation:
Troubleshooting :