Vent  system must terminate  to the outside
(Roof or side wall).
•
DO NOT terminate the vent system in an attic or
other enclosed area.
•
DO NOT  use 4” (10.2 cm) laundry-type  wall
caps.
•
Use metal/aluminum  vent only.  Rigid metal/
aluminum vent is recommended.
•
DO NOT use plastic vent.
•
Always keep the duct clean  to ensure proper
airflow.
•
Calculate  the following figures before
installation:
1. Distance from the floor to the ceiling
2. Distance between the floor to the
countertop/stove
3.
Distance between the cooking surface to the
range hood (recommended
 minimum 24”
electric cooktop, 30” gas cooktop)
4. Height of hood and duct cover
For the most efficient & quiet operation:
•
A distance of 24” minimum is recommended between 
electric  stove top and  the bottom of range  hood,  and 
30” between gas stove top and bottom of range hood. 
Maximum 30".
•
It  is  recommended that  the  range  hood  be  vented
vertically  through  the  roof  through  6”  (15.3  cm)  or
bigger round metal/aluminum vent work.
•
The size of the vent should be uniform.
•
Use no more than three 90° elbows.
•
Make  sure there  is a  minimum  of 24”  (61 cm)  of
straight  vent  between  the  elbows  if  more  than  one
elbow is used.
•
DO NOT install two elbows together.
•
The length  of  vent system  and  number of  elbows
should be kept  to a minimum  to provide  efficient
performance.
•
The vent system must have a damper.  If roof or
wall  cap  has  a  damper,  DO  NOT  use  damper  (if
supplied) on top of the range hood.
•
Use silver tape or duct tape to seal all joints in the
vent system.
•
Use caulking to seal exterior wall or roof opening
around the cap.
VENTING REQUIREMENTS: HEIGHT & CLEARANCE:
5