Installation Guide
1) If  the  range  hood  or  halogen  light  does  not
operate after installation:
2) The range hood  vibrates when  the blower is  on:
3) The blower or fan seems weak:
4) The  lights work  but  the  fan  is not  spinning  at
all, is stuck or is rattling:
5) The hood is not venting out properly:
TROUBLE SHOOTING:
• Check if the range hood has been plugged in,
make sure that all power has been turned back
ON,fused not  blown  and all electrical  wiring
are properly connected.
• The range hood might not have been secured
properly on to the ceiling or wall.
• Check that the duct sized used is at least 6” or
3-1/4 x 10”. Range hood WILL NOT function
efficiently  with  insufficient  duct  size.  For
example: 7” duct over 6”  hole and loosely
secured.
• Check if duct  is clogged  or if  damper unit
(half-circular flange) is not installed correctly
or opening  properly.  A tight  mesh  on a  side
wall cap unit might also cause restriction to the
air flow.
• The fan might be jammed or scraping the
bottom due to shipping damage. Please
contact us immediately.
• Make sure the distance between the stove top
and the bottom of the hood is within 24” and
30”  in distance.
• Reduce  the  number  of  elbows  and  length  of
duct work.  Check  if all  joints  are properly
connected, sealed, and taped.
16