® Slim 30 in. Range Hood User Manual & Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation, safety and maintenance. Keep these instructions for future reference.
Before You Begin INSTALLERS - Start Here Safety Instructions are on pages 4 and 5 and Installation Instructions are on pages 8 to 14. Please perform these steps: 1. Read the safety instructions. 2. Read all instructions in the Installation section of this manual BEFORE installing the range hood. 3. Remove all packing materials. 4. When finished, make sure to leave these instructions with the consumer. 5. Installation is to be done by a qualified technician only.
Table of Contents Before You Begin................................................................................................................................ 2 Table of Contents............................................................................................................................... 3 Important Safety Information............................................................................................................. 4 Included Parts..............................................
Important Safety Information READ ALL INSTRUCTIONS BEFORE USE Read and follow all instructions before using the range hood to prevent the risk of fire, electric shock, personal injury, or damage when using the range hood or appliances with the range hood. This guide does not cover all possible conditions that may occur. Always contact your service technician or manufacturer about problems that you do not understand.
Important Safety Information WARNING: TO REDUCE RISK OF A RANGE TOP GREASE FIRE: To reduce the risk of injury to persons in the event of a gas leaks: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. • Extinguish any open flame. • DO NOT turn on the lights or any type of appliance. • Open all doors and windows to disperse the gas.
Included Parts Range Hood Vent/Damper 2 Filters (30 in.) Rubber bushing 10 + 1 mounting screws Cable tie Hardware Note: For safety reasons, range hood mounting screws and anchors will not be included due to the variation of cabinetry constructions and wall material. Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home’s construction.
Range Hood Dimensions 5c (1.9 m 6 in ./po 8.3 cm (3 . 25 .6 cm in./ po (25 1 13/ (11. 8 in in./ po) ) /po n. 6i ) 10 ./po ) cm 12.7 cm (5 in./po) 16 65 1/4 m( ( 1 3/4 in./po) ) /po in. 1 cm 4c 4.5 cm m 5c ( 10 30. 25. ) 48 cm /2 91 (19 m 5c ) po (2 7 in./ po) 7.2 cm (2 .83 in./p o) 25.5 cm ( 10 in.
Installation STEP 1 Read the Safety Instructions • It is very important to read the safety instructions on pages 4 and 5. IMPORTANT: It is the installer’s responsibility to comply with installation clearances. STEP 2 Unpack Range Hood and Prepare Tools • Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6. • DO NOT remove the protective film covering the appliance until the installation is fully completed.
Installation STEP 5 Venting Installation Guidelines • The following steps are for exterior ventilation. IMPORTANT: • Vent system must terminate to the outside (roof or side wall). • DO NOT terminate the vent system in an attic or other enclosed area. • DO NOT use 4 in. (10.2 cm) laundry-type wall caps. • Use metal/aluminum vent only. A rigid metal/aluminum vent is recommended. • DO NOT use a plastic vent. • Always keep the duct clean to ensure proper airflow.
Installation IMPORTANT: • A minimum of 6 in. (15.2 cm) round or 3-1/4 x 10 in. (25.4 cm x 8.3 cm) rectangular duct (purchased separately) must be used to maintain maximum airflow efficiency. • Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct. • Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps. • ALWAYS, when possible, reduce the number or transitions and turns.
Installation • If performing new installation, please follow Step 6 • If performing replacement installation, please skip Step 6 and continue to Step 7 STEP 6 Create Exterior Ventilation (New Installation Only) • Choose one of the exterior venting methods shown on Page 10. • Create the exterior ventilation hole. • Insert exterior damper into exterior ventilation hole.
Installation STEP 8 Attaching Vent/Damper • Depending on the exterior venting option chosen (See page 10), pop out the steel panel on either the top or rear of the range hood. (See Fig #2) • Using the supplied screws, attach the rectangular vent/ damper to the rear of the range hood. (See Fig #3) Fig #2 Fig #3 STEP 9 Installing the Hood • Using measurements provided on Page 7, measure and drill 4 holes into bottom of cabinet.
Installation IMPORTANT: • Observe all governing codes and ordinances. • It is the customer’s responsibility to contact a qualified electrical installer. • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. • DO NOT ground to a gas pipe.
Installation STEP 12 Install Filters To install filters follow these four steps (See Figure #7): • Angle the filter into slots at the back of the hood. • Push the button on handle of the filter. • Release the handle once the filter fits into a resting position. • Repeat to install all filters.
Operation 15 minute delay On / Speed Up Off / Slow down LCD Power settings Light Timer Function u Press the button once and the motor starts to operate at Low speed. The control module provides the option to run the motor for a predetermined time period in order to evacuate remaining vapors from the kitchen. v Press the button again and the motor will reach Medium speed. u w Press the button once more and the motor will reach High speed Press the button while the motor is running.
Troubleshooting Problem Possible Cause If the range hood or LED light Check if the range hood has been plugged in, make sure that all power does not operate after installation: has been turned back ON, fused not blown and all electrical wiring are properly connected. The range hood vibrates when the The range hood might not have been secured properly on to the ceiling or blower is on: wall. The blower or fan seems weak: Check that the duct sized used is at least 6 in. (15.2 cm) or 3 1/4 x 10 in. (25.
Range Hood Assembly Number 1 LED puck lights 2 Lamp board 3 Baffle filters (2 pieces) Electrical box support 4 5 — 17 — Part 6 Electrical box bottom cover Capacitor 7 Right Cage plate 8 Right Propeller cage 9 PCB 10 LED lamp driver 11 Electrical box cover 12 Driver guide line 13 Touch Switch board 14 Touch Switch support 15 Touch Switch 16 Electrical wire 17 Outlet 18 19 Touch switch guide line Motor 20 Lamp guide line 21 Safety Screen 22 Left Cage plate 23 Left Pro
100.00 mm Assembly 60.00 mm Circuit Diagram BLOWER ASSEMBLY: No. 1 Motor cage 2 Motors 3 Fly Wheels Description No. Descripti 4 Safety screens Blower assembly Number 1 2 Part Propeller Cage Motor 3 Propeller 4 Cage Plate 5 Safety Screen ELECTRICAL ASSEMBLY: No. 1 2 3 4 5 Description Electrical box cover PCB Electrical box base Capacitor Set Up Board Electrical Assembly Number 1 Part Electrical box cover 2 PCB 3 Electrical box base 4 Capacitor 5 Set Up Board — 18 — No.
Use and Care Information Operations • Read and understand all instructions and warnings in this manual before operating the appliance. Save these instructions for future reference. • Always leave safety grills and filters in place. Without these components, operating fans could catch on to hair, fingers and loose clothing. • NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into fans. • NEVER leave cooking unattended.
Please register your product warranty by visiting the Ancona Home website. Canada & USA Phone: 1-888-686-0778 Fax: 800-350-8563 Email: service@anconahome.com Website: www.anconahome.com Ancona is in association with Mr Appliance for all after sales service calls. Please contact their service provider or visit their website: Phone: 1-888-998-2011 Website: www.mrappliance.com © 2018 Copyright of Ancona Home. All rights reserved. This material may not be reproduced, displayed, modified or distributed.