Electrical Requirements:
IMPORTANT: Observe all governing codes and ordinances. 
It is the customer’s responsibility: 
• To contact a qualified electrical installer.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that 
the ground path is adequate. 
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides 
of the line. 
DO NOT ground to a gas pipe. 
Check with a qualified electrician if you are not sure that the range hood is properly grounded. 
DO NOT have a fuse in the neutral or ground circuit. 
IMPORTANT: Save this Installation Guide for electrical inspector’s use. 
The range hood must be connected with copper wire/plug only. 
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible
armored or non-metallic sheathed copper cable. ETL- listed strain relief must be provided at each 
end of the power supply cable. 