•  Vent  system  must  terminate  to  the  outside
  (Roof or side wall).
•  DO  NOT  terminate  the  vent  system  in  an  attic
  or other enclosed area.
•  DO  NOT  use  4”  (10.2  cm)  laundry-type  wall
  caps.
•  Use  metal/aluminum  vent  only.  Rigid  metal/
  aluminum vent is recommended.
•  DO NOT use plastic vent.
•  Always  keep  the  duct  clean  to  ensure  proper
  airflow.
•  Calculate  the  following  figures  before
  installation:
  1. Distance from the floor to the ceiling
  2. Distance between the floor to the     
   countertop/stove
  3. Distance between the cooking surface to
   the range hood (recommend 24” to 30”) 
   minimum of 30” is required for gas cook top
  4. Height of hood and duct cover
For the most efficient & quiet operation:
•  A  distance  of  24”  to  30”  is  recommended
  between  stove  top  and  the  bottom  of  range
  hood. 30” minimum is required for gas stove tops.
•  It  is  recommended  that  the  range  hood  be 
  vented  vertically  through  the  roof  through  6”
  (15.3  cm)  or  bigger  round  metal/aluminum 
  vent work.
•  The  size  of  the  vent  should  be  uniform.
•  Use  no  more  than  three  90°  elbows.
•  Make sure there is a minimum of 24” (61 cm) of
  straight vent between the elbows if more than one 
  elbow is used.
•  DO NOT install two elbows together.
•  The length of vent system and number of elbows
  should be kept to a minimum to provide efficient
  performance.
•  The vent system must have a damper. If roof or 
  wall cap has a damper, DO NOT use damper (if
  supplied) on top of the range hood.
•  Use silver tape or duct tape to seal all joints in the
  vent system.
•  Use caulking to seal 
exterior wall or roof opening
  around the cap.
VENTING REQUIREMENTS: HEIGHT & CLEARANCE:
Max:
108.85”
Min: 24”
Max: 30”
Maximum
ceiling clearance
at 112 7/8”
at 30” clearance
above
countertop/stove.
Chimney mounting bracket
Upper chimney
Lower chimney
Range hood
Countertop / Stove