User guide

X-9
Interchangeability
Rafter Chart
• Consult the rafter chart above in selecting the components needed for the span
you intend to install. Please note that:
All spans use (2) base columns and (1) apex. The base column is a male piece
at the upper end. The apex is female on both ends.
• The 60ft span uses only a pair of long rafters (15’-11 9/16”) to complete the beam arch.
• The 70ft span uses two pair of shorter rafters (10’-7 11/16”) to complete the beam arch.
• The 80ft span uses a pair of short rafters and a pair of long rafters,
positioned as shown above, to complete the beam arch.
• Male ends of the base column and all
rafters point toward the apex in all spans.
Male ends consist of pre-installed splices protruding from the end of beam section.
We suggest leaving these splices installed during storage of beams.
NOTE: We have alternate 5’-3” rafters for 40’ spans. The apex and two base columns,
alone, form a 30’ unit.
40’
This pattern-coded diagram shows the common beam sections shared to allow the
reconfiguration of the 80’ wide unit into the 70’, 60’, 50’, and 40’ wide units.
50’
60’
70’
80
60’ Rafter (15’-11”)
50’ Rafter (10’-7”)
Apex
Base
Column
Alternate
40’Rafter
(5’-3”)