7.3.11 24V Control Circuit Supply
The maximum current that can be drawn from this supply is 500mA total. Note that if a motor with a brake is
required this may be insufficient current to release the brake, so an external power supply will be required. Also
note that if overloaded the polyfuse in the drive will present a high resistance and there will no longer be 500mA
available until the load is removed.
7.3.12 Digital Inputs
Digital Input Overview
DI-01 DI08 are electrically isolated through opto-couplers.
DI-09 DI10 are not isolated.
Reference ground is +24V-GND (X4 pins 46 & 47)
Application examples for the digital inputs includes:
Positive Limit switch
Motor over-temperature
Negative Limit switch
Home switch
General Purpose Digital Inputs DI-01 to DI-08 7.3.12.1
Warning: Please refer to section 12.3 Interface Specifications for detailed current ratings of the 24V supply if
used to switch I/O devices
Idealized Drawing of Input Circuit 7.3.12.1.1
AMD2000
DI-XX
DSP