User`s manual
Table Of Contents

AIR B-Smart BoosterPack – User’s Manual Page 12 of 33
Release Date 11/04/13
3. AIR B-Smart BoosterPack Hardware
3.1. Electrical Characteristics
3.1.1. Absolute Maximum Ratings
Under no circumstances shall the absolute maximum ratings given in Table 2 be violated.
Stress exceeding one or more of the limiting values may cause permanent damage to the
device.
Table 2 - Absolute Maximum Ratings
Parameter
Min
Max
Unit
Condition
Supply
Voltage
-0.3
3.9
V
Voltage
On Any
Digital Pin
-0.3
VDD + 0.3
max 3.9
V
Input RF
Level
+10
dBm
Storage
Temperature
Range
-40
125
°C
ESD
2000
V
According to JEDEC STD 22,
method A114, Human Body Model (HBM)
500
V
According to JEDEC STD 22, C101C,Charged
Device Model (CDM)
3.1.2. Recommended Operating Conditions
Table 3 – Recommended Operating Conditions
Parameter
Min
Max
Unit
Condition
Operating Supply Voltage
2.0
3.6
V
Operating Temperature
-40
+85
°C
Caution!
ESD sensitive device. Precaution should be
used when handling the device in order to
prevent permanent damage.