User manual
FAQ - Frequent asked questions
16 © 2007-2010 Analytica GmbH
Table A.1. Using AnaGate hardware with firewall
Device Port number
AnaGate I2C 5000
AnaGate CAN 5001
AnaGate CAN USB 5001
AnaGate CAN uno 5001
AnaGate CAN duo 5001, 5101
AnaGate CAN quattro 5001, 5101, 5201, 5301
AnaGate SPI 5002
AnaGate Renesas 5008
AnaGate Universal Programmer 5000, 5002, 5008
A.2. Questions concerning AnaGate CAN
Q:
What is the value of the termination resistor when the termination option of the device is activated?
A:
The termination resistor of the AnaGate is driven by an FET transistor. The resistor itself has 110
Ohm while the internal resistance of the FET is 10 Ohm if the FET is activated. So the resulting
resitance is 120 Ohm, as required by the CAN bus.
Q:
Does Analytica offer a CAN gateway which does not have an galvanically isolated CAN interface?
A:
Any device that is actively connected to a CAN bus should be galvanically isolated. Especially when
using USB-operated devices (like the AnaGate USB), it is essential to have an galvanically isolated
device, because the device is power supplied by the PC.