User manual
Configuration
10 © 2007-2010 Analytica GmbH
2.5.2. Connecting the digital outputs
The outputs are implemented as open collector drivers. If a output is active, it is pulled down to GND. In
the inactive condition the output is floating.
In principle the maximum current of each individual output is 400mA. For thermal reasons is the sum
of all output currents is limited to 500mA. The outputs not short-circuit proofed, and must be protected
with a pre-resistor.
2.6. Firmware update
Use the Firmware page to load a new firmware to the AnaGate CAN Gateway.
Please visit our Web site http://www.anagate.de for further information.
2.7. Factory reset
In order to restore the default factory settings, hold the RESET for approx. 10 seconds. If the device is
reset successfully, the yellow LED blinks until the RESET is released.
The default factory settings are activated immediately without a restart of the device:
IP address 192.168.1.254
Address type static
Network mask 255.255.255.0
Gateway 192.168.1.1
Important
If the RESET push-button is pressed too briefly, the actual IP address and network mask
is pulsed via the yellow LED (Morse code). A second push of the RESET, terminates the
pulsing, the device is not reset.
Note
The factory reset is not possible directly after power on until complete loading of operating
system and firmware of the device. This initialization period is signalled via the yellow
activity LED. On power on the LED is switched on and after initialization the LED is
switched off.
Note
Maybe the ARP cache of the PC has to be deleted to find the device with the changed IP
address.
2.7.1. Examining the network settings
It is possible to check the current network settings directly on the device.
After pressing shortly the RESET button the device starts to pulse out the current n settings via the yellow
activity LED. Pressing again the buttons stops the pulsing immediately.
The IP address and subnet mask are pulsed out, one after the other. Following pulse codes are used: