User manual
Configuration
7 © 2007-2010 Analytica GmbH
Figure 2.3. HTTP interface, CAN settings
Baudrate The baud rate can be selected easily via a list box containing all supported
values.
Termination Use the check box to switch on/off the internal termination resistor.
High Speed Activates/deactivates the Highspeed mode. In this operating mode all
incoming/outgoing CAN telegrams are not longer confirmed by the opposite
LAN side to accelerate process throughput. Software-Filters are switched off
too in this mode.
Bridge Activates/deactivates the bridge mode (see Section 3.2, “ Bridge mode”).
to IP IP address of the partner device, to which a connection (bridge) is to be made
(only Bridge Modus).
at Port Port of the partner device, to which a connection (bridge) is to be made (only
Bridge Modus).