User manual

Fields of application
19 © 2007-2014 Analytica GmbH
The baudrate of the partner device. The baudrate of the parter device is
independant of the own baudrate and has to be configured separatly. So, it is
possible to interconnect networks with different baudrates.
The internal termination resistor is to be set on/off for the CAN port of the parter
device. On destination devices, which can not software-configure the CAN bus
termination (like the AnaGste CAN X2/X4/X8), this setting is ignored.
When the AnaGate CAN Gateway establishes the connection to the partner device
succesfully, the specified baud rate and integrated termination option is automatically
set on the partner device.
Tip
It is recommended to configure the operational mode of the AnaGate
CAN Gateway, which is connected by the active device, to offline or
normal (together with the valid baud rate). This reduces the risk that
error frames are created on the local CAN network, because of an invalid
configured baud rate during startup phase until the successful established
TCP interconnection.
Figure 3.3. Bridge mode: Setting for device which initiates the
bridge (here AnaGate CAN uno)
Note
On the models with more than one CAN interface, it is possible to
interconnect one CAN interface to another interface of the same device
(this is called internal bridge).