User manual

Fields of application
18 © 2007-2014 Analytica GmbH
Self-created batch files which are executed via the included Lua interpreter with
integrated AnaGate software API.
3.2. Bridge mode
In the bridge mode two arbitrary CAN networks can be interconnected by two
AnaGate CAN Gateways. The CAN messages are exchanged transparently over TCP/
IP between the two devices in both directions.
It is possible to mix different AnaGate CAN Gateway models in bridge mode.
Important
It is recommended to use unique CAN identifiers in the interconnected
CAN networks.
Via HTTP interface both AnaGate CAN Gateway are configured as usual.
Subsequently one of the two devices has to be configured for the bridge mode. This
can be done by the page CAN Settings of the web interface (see Section 2.3, “ CAN
settings”). This device acts in a manner of speaking as master and establishes the
network connection to the second device and manages connection control. Basically
a bridge can be created for each existing CAN interface of the device.
Figure 3.2. AnaGate CAN Gateway in bridge mode
The following additional parameters can be set for the device:
IP address of the partner device, which is to be connected.
CAN port of the partner device, which is to be connected (see Table A.1, Using
AnaGate hardware with firewall ”).