User manual
Configuration
14 © 2007-2014 Analytica GmbH
Warning
The outputs are not short-circuit-safe!
2.8. Factory reset
In order to restore the default factory settings, hold the RESET for approx. 10
seconds. If the device is reset successfully, the yellow LED blinks until the RESET
is released.
The default factory settings are activated immediately without a restart of the device:
IP address 192.168.1.254
Address type static
Network mask 255.255.255.0
Gateway 192.168.1.1
Important
If the RESET push-button is pressed too briefly, the actual IP address and
network mask is pulsed via the yellow LED (Morse code). A second push
of the RESET terminates the pulsing, the device is not reset.
Note
The factory reset is not possible directly after power on until complete
loading of the operating system and the firmware of the device. This
initialization period is signalled via the yellow activity LED. On power on
the LED is switched on and after initialization the LED is switched off.
Note
Maybe the ARP cache of the PC has to be deleted to find the device with
the changed IP address.
2.8.1. Examining the network settings
It is possible to check the current network settings directly on the device.
After pressing shortly the RESET button the device starts to pulse out the current
n settings via the yellow activity LED. Pressing again the buttons stops the pulsing
immediately.
The IP address and subnet mask are pulsed out, one after the other. Following pulse
codes are used:
• Digits 1, 2, 3, ...., 9: 1x, 2x, ...9x Flashing (200ms delay between each flash)
• Digit 0: 10x flashing (200ms delay between each flash)
• Dot: 1x very fast flash