Product Manual

5
Specications
Model VTC605-12-12 VTC605-12-24
Input Voltage 10.5 - 18 VDC 10.5 - 28 VDC
Output Voltage
(Input – 1V) or 13.5 - 17.0 VDC
Whichever is greater
(Input – 1V) or 24.0 - 27.5 VDC
Whichever is greater
Current Limit 50 Amps In
Output Crowbar Programmed Output Volts x (1.3 ± 1%)
Input Fuse AGC 30 Amp X 2
Low Input Voltage Alarm 10.5 VDC
Low Output Voltage Alarm Programmed Output Voltage minus 2.5 VDC
Noise on Input < 50 milli-volts
Noise on Output < 50 milli-volts
Transient Resp. < 1V for 30A Surge
Efciency > 90 % @ maximum output
Temp. Range -25 to +40 deg° C @ maximum output
Isolation
Any Input or Output to Case 500VDC
Input to Output Common Negative
Length 9.1 in / 23.1 cm
Width 7.8 in / 19.8 cm
Height 4.3 in / 10.8 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Black Powder Epoxy
Fastenings 18-8 Stainless
Weight 6.0 lb / 1.8 kg.
* Specications subjects to change without notice.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com analyticinfo@analyticsystems.com Revised August 2014