MODEL
VTC120i Series
Isolated
Model (VTC120) i-12-12 i-12-24 i-24-12 i-24-24 i-48-05 i-48-12 i-48-24 i-48-48
Input Volts (DC) 11 – 15 11 – 15 22 - 30 22 - 30 40 – 60 40 – 60 40 – 60 40 – 60
Input Amps (max) 8.5 15 3.8 7.5 1 2.1 4.2 8.4
Input Fuse AGC-10 AGC-20 MDA-6 AGC-10 MDA-2 MDA-3 MDA-5 MDA-10
Output Volts (DC) 12.0 24.0 12.0 24.0 5.0 12.0 24.0 48.0
Output Amps 5 Continuous / 5.5 Peak
2.5 Cont. /
5.5Peak
Isolation Input-Output > 500 VDC
Isolated (High)
Model (VTC120) ih-12-12 ih-12-15.6 ih-12-24 ih-24-12 ih-24-24 ih-36-15.6 ih-48-15.6 i-48-12
Input Volts (DC) 11 – 15 11 – 15 11 – 15 22 - 30 22 - 30 33 – 45 40 – 60 40 – 60
Input Amps (max) 11 14.2 21.8 6.2 10.9 4.8 3.9 3.0
Input Fuse AGC-15 AGC-20 AGC-25 MDA-7 AGC-15 MDA-8 MDA-7 MDA-5
Output Volts (DC) 12.0 15.6 24.0 12.0 24.0 15.6 15.6 12.0
Output Amps 7.5 Continuous / 8.0 Peak
Isolation Input-Output > 500 VDC
Electrical (General)
Noise on Input < 5 mV
Output Ripple & Noise < 5 mV
Transient Response < 1V for 50% Surge
Regulation (Line & Load) < +/- 0.5%
Duty Cycle
Peak 20% for 10 min maximum
Continuous 100% for 24 hours per day
Efciency > 80% @ Maximum Output
Environmental Specication
Operating Temp. Range
-25°C to +40°C @ maximum output
Derate Linearly 2.5% per °C from 40°C
(Optional -40°C - +55°C extra wide temp. operation avail.)
Humidity
0 - 95% Relative Humidity
(non-condensing) with standard conformal coating
Audible Noise NONE Ødb @ 3 ft
Typical Service Life > 10 yrs. (87,600 hrs)
Isolation Any Input or Output to Case 500 VDC