5
Isolated High Output
Model (VTC120) ih-12-12 ih-12-15.6 ih-12-24 ih-24-12 ih-24-24 ih-36-15.6 ih-48-15.6 ih-48-12
Input Volts (DC) 11 – 15 11 – 15 11 – 15 22 - 30 22 - 30 33 – 45 40 – 60 40 – 60
Input Amps (max) 11 14.2 21.8 6.2 10.9 4.8 3.9 3.0
Input Fuse AGC-15
AGC-20
AGC-25 MDA-7 AGC-15
MDA-8 MDA-7 MDA-7
Output Volts (DC) 12.0 15.6 24.0 12.0 24.0 15.6 15.6 12.0
Output Amps 7.5 Continuous / 8.0 Peak
Isolation Input-Output > 500 VDC
* Specications subjects to change without notice.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way, Delta, BC V4G 1K5
Canada
p. 604.946.9981 f. 604.946.9983 tf. 800.668.3884 US/Canada
www.analyticsystems.com sales@analyticsystems.com
Installation
MOUNTING
Mount the unit in a DRY location. Allow at least 1 inch of clearance around the unit for
adequate cooling.
INPUT
VOLTAGE CONVERTER
OUTPUT
ANALYTIC SYSTEMS
ii - II VDC
FUSE
oo.o VDC AGC XXA
XX AMP CONT.
ZZ AMP PEAK
MADE IN CANADA
800-668-3884
IN
IN
OUT
OUT
FUSE