VCH10 Series Datasheet
INPUT
Model VCH10-12 VCH10-24 VCH10-32 VCH10-36 VCH10-48
Input Volts 20 - 80 VDC 30 - 80 VDC 40 - 80 VDC 45 - 80 VDC 60 - 80 VDC
OUTPUT VOLTS
Nominal 12 VDC 24 VDC 32 VDC 36 VDC 48 VDC
Actual 13.6 VDC 27.2 VDC 36.3 VDC 40.8 VDC 54.4 VDC
OUTPUT
Output Amps 10 Amps
Dissipation 12 Watts
Efciency 91.9% 95.8% 96.8% 97.1% 97.8%
MECHANICAL
Dimensions
4.85 in / 12.3 cm Long x 4.13 in / 10.5 cm Wide (incl. mounting anges)
x 1.03 in / 2.6 cm High
Clearance 1.0 in / 2.5 cm all around
Weight 0.62 lb / 0.28 kg
Material and Finish Marine grade aluminum with red anodize cover / black anodize chassis
Mounting Wall or shelf mount
Connections Pluggable Phoenix Combi-Com four position terminals
ELECTRICAL
Input Ripple & Noise < 100 mV Peak to Peak
Output Ripple & Noise < 50 mV Peak to Peak
Transient Response < 300 mV for 50% Load Step Change
Regulation (Line & Load) < +/- 0.5%
OPTIONS
Heavy duty ruggedization with
wide temperature range
Paralleling diodes
Custom output voltages available
DIMENSIONS
FEATURES
VCH10 | DC/DC VOLTAGE CONVERTER
3.29
4.85
3.50
0.68
1.03
0.17
ENVIRONMENTAL AND SAFETY
Operating Temperature Range
-25°C to +40°C @ maximum output. Derate Linearly 2.5% per °C from 40°C
(Optional -40°C wide temperature range available)
Humidity 0 - 95% Relative Humidity (non-condensing) with standard conformal coating
Audible Noise NONE 0db @ 3ft
Typical Service Life > 10 years (87,600 hrs)
Isolation >1500 VDC Input-Output, Input-Case, Output-Case
Warranty Three years parts and labor
Safety Built to meet CSA 22.2.107.1 & UL458
AnalyticSystems.com
sales@analyticsystems.com
604.946.9981 800.668.3884
8128 River Way
Delta BC V4G 1K5
Simple plug in wiring