VCH10 Series Manual

5
Specications
Input
Model VCH10-12 VCH10-24 VCH10-32 VCD10-36 VCH10-48
Input Volts VDC 20 - 80 30 - 80 40 - 80 45 - 80 60 - 80
Input Fuse CB61F15A - 15 Amp Surface Mount
Output
Nominal VDC 12 24 32 36 48
Actual 13.6 27.2 36.3 40.8 54.4
Output Amps 10 Amps
Dissipation 12 Watts
Efciency 91.9% 95.8% 96.8% 97.1% 97.8%
Electrical
Input Ripple & Noise < 100 mV Peak to Peak
Output Ripple & Noise < 50 mV Peak to Peak
Regulation (Line & Load) < +/- 0.5%
Mechanical
Dimensions
4.85 in / 12.3 cm Long x 4.13 in / 10.5 cm Wide (incl. mounting anges)
x 1.03 in / 2.6 cm High
Clearance 1.0 in / 2.5 cm all around
Weight 0.62 lb / 0.28
Material and Finish Marine grade aluminum with red anodize cover / black anodize chassis
Mounting Wall or shelf mount
Connections Pluggable Phoenix Combi-Com four position terminals
Environmental and Safety
Operating Temperature Range 25°C to +40°C @ maximum
Humidity 0 - 95% Relative Humidity (non-condensing) with standard conformal coating
Audible Noise None
Typical Service Life 10 years (87,600 hrs)
Isolation Any input or output to case (1500 VDC). Input to output - common negative
Warranty Three years parts and labor
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com info@analyticsystems.com
* Specications subjects to change without notice.