Troubleshooting
This unit provides LED indicators and a buzzer to help diagnose any problems. The unit should 
sound the buzzer to alert you prior to shutting itself down. You should immediately check the 
indicators to determine the cause of the shutdown.
LOW OUTPUT  Indicates that the output voltage is below normal because:
• The current demanded by the devices connected to the unit exceeds the maximum 
output current rating, causing the output voltage to drop to maintain the current at 
the maximum level,
• The input voltage is not high enough for unit to operate,
LOW INPUT  Indicates that the input voltage is below normal because:
• The input voltage is not in the correct range for proper operation of the unit.
OVERTEMP  Indicates that the Battery Charger is running too hot because:
• Too much power is being drawn, turn off or unplug some devices.
• The Battery Charger is located in a poorly ventilated area.
OVERLOAD  Indicates that the load it trying to draw to much current because:
• Too much power is being drawn, turn off or unplug some devices.
If the load exceeds the continuous rating for too long a period, the temperature sensor inside 
the unit will turn off the outputs. After the unit cools sufciently, it will automatically come 
back on. If this happens frequently, remount the unit for increased airow so it cools better.