IPSi365 Series Datasheet

OUTPUT -110 -220
Nominal Voltage 110 VAC 220 VAC
Output Current 3 A (Continuous) / 3.6 A (Peak) 1.5 A (Continuous) / 1.8 A (Peak)
Output Voltage Adjustment ±10 VAC ± 20 VAC
Regulation (Line & Load) +/- 2 VAC +/- 3 VAC
Output Frequency 50 or 60 Hz (User-selectable)
Output Distortion (THD) < 2% @ 360 VA Resistive load
Duty Cycle 24 hours/day @ 100% / 1 min @ peak with 10 min cooldown
Efciency 85% @ Full Load
Ground Fault Trip Current 4-6 mA
INPUT -12 -20 -40
Nominal Voltage 12 VDC 24, 28, 32 or 36 VDC 48 or 72 (Rail) VDC
Actual Voltage 10.5-18 VDC 19-48 VDC 39-84 VDC
Maximum Current 49 A 28 A 14 A
Input Fuse
2x 30A 32 VDC Blade
Mini Fuses
1x 30A 58 VDC Blade
Mini Fuse
1x MDA - 15 A Fuse
Low Voltage Input
Shutdown Range
10.5-14 VDC Range
(Default setting: 10.5 VDC)
19-36 VDC Range
(Default setting: 21 VDC)
39-70 VDC Range
(Default setting: 42 VDC)
Low Voltage Input
Startup Range
11-14 VDC Range
(Default setting: 11.5 VDC)
20-36 VDC Range
(Default setting: 23 VDC)
40-70 VDC Range
(Default setting: 44 VDC)
Low Voltage Input
Shutdown Delay
1-120 seconds (Default setting: 30 seconds)
High Volt. Input Shutdown 19 VDC 49 VDC 86 VDC
Inrush Current (From fully
discharged)
1.8 Amp Peak 4.8 Amp Peak 8.4 Amp Peak
MECHANICAL
Dimensions 13.0 in / 32.8 cm x 8.0 in / 20.3 cm x 3.3 in / 8.3 cm (Length x Width x Height)
Clearance 1.0 in / 2.5 cm all around
Weight 16.0 lb / 7.3 kg
Material and Finish Marine Grade Black Anodized Aluminum
Fasteners 18-8 Stainless Steel
Output Connections
Hardwire: Phoenix VDFK4 32 Amp / 500V terminal block
110 VAC Model: NEMA 5-15 receptacle
220 VAC North America Model (220N): NEMA 6-20 receptacle
220 VAC Worldwide Model (200W): 220V Universal receptacle
Input Connections
AC: Phoenix VDFK4 32 Amp / 500V terminal block (A Option Only)
DC: Phoenix VDFK6 50 Amp / 300V terminal block
Other Connections
Data/Communication: MicroUSB port
Remote Control: RJ45 ‘telephone jack’ connector with proprietary pinout
ENVIRONMENTAL AND SAFETY
Operating Temperature
-25°C to +40°C @ Full Load (-40°C to +55°C extended operating
temperature option available)
Storage Temperature -55°C to +105°C
Cooling Thermostatically-controlled cooling fan
Humidity 0 - 95% relative humidity (non-condensing) with standard conformal coating
Audible Noise < 27 dB @ 3 ft/ 1m with fan running
Typical Service Life > 10 years (87,600 hrs)
Isolation Input to Chassis: <1100VDC. Input to Output, Output to Chassis: <1500 VAC
Warranty Three Years Parts and Labor
Safety Complies with FCC Class B, Part 15
DIMENSIONS
IPSi365 | INTELLIGENT PURESINE INVERTER
Analyticsystems.com
Sales@Analyticsystems.com
604.946.9981 800.668.3884
101-8128 River Way
Delta, B.C. V4G 1K5
Note: Specications are subject to change without notice.
OPTIONS
Military Ruggedization: MIL-Spec connectors
and features extra-wide operating temperature
-25°C to +55°C
COTS: Military ruggedization package with both
MIL461F and MIL810G compliance testing with
reports
Special Safety Inspection: Inspected and
certied to meet CSA C22.2 No.107.1 and UL 458
Ofine UPS: Built with AC Input and Line AC
Detect & Autoswitch UPS
Remote Control: Built the remote control port and
supplied with Analytic Systems digital remote
control.
Worldwide 220V
Outlet (220W Option)
North America 220V
Outlet (220N Option)
Hard Wired Connection
(Can be combined with
any outlet)
ALTERNATIVE 220V OUTLETS