IPSi305W_Manual

98
CAUTION: DO NOT APPLY AC VOLTAGE TO THE AC OUTPUT CONNECTION!
This will damage the inverter and will not be covered under warranty.
DC Connections
AC Connections
DC INPUT CONNECTION
This unit is equipped with an CNLINKO IP67 YM-20-C02SX-01-001 connector with protective
cover to serve as a DC Input Connection. Connect the DC power source here using wiring
suitable for the input amps. The maximum input amps can be found on the unit’s top panel
label and also in the Specications section.
The polarity of this connection can be found on the label on the unit’s front panel and also in
the table below.
AC OUTPUT CONNECTION
This unit is equipped with an CNLINKO YM-20-J03SX-01-001connector with protective cover
to serve as an AC Output Connection.
Connect the AC load here using wiring suitable for the expected output. The maximum output
current can be found on the unit’s top panel label and also in the Specications section.
Pin Polarity
Pin 1 AC Hot/Live
Pin 2 AC Neutral
Pin 3 AC Ground (Chassis)
Pin Polarity
Pin 1 DC Input Positive
Pin 2 DC Input Negative
CAUTION: DO NOT REVERSE CONNECT THE DC INPUT POWER!
This will damage the inverter and will not be covered under warranty.
IMPORTANT: BEFORE CONNECTING OR DISCONNECTING ANYTHING TO THE
INVERTER, THE POWER SWITCH MUST BE TURNED OFF.