IPSi305W_Datasheet

OUTPUT -110 -220
Nominal Voltage 110 VAC 220 VAC
Continuous Amps 2.5 A 1.3 A
Peak Amps 3 A 1.5 A
Output Voltage Adjustment ±10 VAC ± 20 VAC
Regulation (Line & Load) +/- 2 VAC +/- 3 VAC
Output Frequency 50.00 or 60.00 Hz ± 0.01 Hz (User-selectable)
Output Distortion (THD) < 2% @ 360 watts into resistive load
Duty Cycle
Continuous: 24 hours per day @ output
Peak: 1 min per 10 min cool down @ output
Efciency 85% @ Full Load
Ground Fault Trip Current 4-6 mA
INPUT -12 -20 -40
Nominal Voltage 12 VDC 24, 28, 32 or 36 VDC 48 or 72 (Rail) VDC
Actual Voltage 10.5-18 VDC 19-48 VDC 39-84 VDC
Maximum Current 49 A 28 A 14 A
Input Fuse
2x 30A 32 VDC Blade Mini Fuses 1x 30A 58 VDC Blade Mini Fuse 1x MDA - 15 A Fuse
Low Voltage Input
Shutdown Range
10.5-14 VDC Range
(Default setting: 10.5 VDC)
19-36 VDC Range
(Default setting: 21 VDC)
39-70 VDC Range
(Default setting: 42 VDC)
Low Voltage Input
Startup Range
11-14 VDC Range
(Default setting: 11.5 VDC)
20-36 VDC Range
(Default setting: 23 VDC)
40-70 VDC Range
(Default setting: 44 VDC)
Low Voltage Input
Shutdown Delay
1-120 seconds (Default setting: 30 seconds)
High Volt. Input Shutdown 19 VDC 49 VDC 86 VDC
Inrush Current (From fully
discharged)
1.8 Amp Peak 4.8 Amp Peak 8.4 Amp Peak
MECHANICAL
Length 13.0 in / 32.8 cm
Width 8.0 in / 20.3 cm
Height 3.3 in / 8.3 cm
Clearance 1.0 in / 2.5 cm all around
Weight 16.0 lb / 7.3 kg
Material and Finish Marine grade black anodized aluminum
Fasteners 18-8 stainless steel
Input Connection CNLINKO YM-20-J03SX-01-001connector c/w protective cover
Output Connection CNLINKO IP67 YM-20-C02SX-01-001connector c/w protective cover
Other Connections
Data/Communication: MicroUSB port c/w protective cover
Remote Control: RJ45 connector with proprietary pin-out c/w protective cover
ENVIRONMENTAL AND SAFETY
Operating Temperature -25°C to +40°C @ Full load (Expanded -40°C to +55°C range available)
Storage Temperature -55°C to +105°C
Packaging Sealed to meet IP66
Humidity 0 - 95% relative humidity (non-condensing) with standard conformal coating
Audible Noise None, 0dB @ 3 ft
Typical Service Life > 10 years (87,600 hrs)
Isolation
Input to Chassis: <1100VDC.
Input to Output, Output to Chassis: <1500 VAC
Warranty Three Years Parts and Labor
Safety Complies with FCC Class B, Part 15
IPSi305W | INTELLIGENT PURESINE INVERTER
Analyticsystems.com
Sales@analyticsystems.com
604.946.9981 800.668.3884
101-8128 River Way
Delta, B.C. V4G 1K5
Note: Specications are subject to change without notice.
OPTIONS
IP67: Sealed to meet the IP67
rating with in-house testing and
certication
Special Safety Inspection:
Inspected and certied to meet CSA
C22.2 No.107.1 and UL 458
Off-line UPS: Built with AC Input
and Line AC Detect & Autoswitch
UPS
DIMENSIONS