Product Manual
5
Installation
MOUNTING
Mount the unit in a DRY location. Mount the unit in a ventilated area. Allow at least 1 inch of 
clearance around the unit for adequate cooling.
CAUTION: The case of the inverter is connected to AC Ground and AC Neutral to meet 
regulatory requirements and to reduce the possibility of it generating any radio frequency 
interference. The case must be bonded appropriately to the grounding system of the vehicle or 
marine vessel. On a vehicle bond the case to the frame and on a marine vessel bond the case 
to the hull. A grounding stud is provided on the front of the inverter for this purpose. To ensure  
proper grounding, check the connection with an ohmmeter. The case is isolated from the DC 
Input, so the DC power can be on a different ground from the AC output.
CAUTION: Do not mount the unit where explosive gases may accumulate as a slight arc may 
occur when the power leads are connected, and in the unlikely event of a failure, sparks may 
be generated inside the unit.
INPUT CONNECTION
Prepare a circuit breaker protected power source for the IPSi1200 Series Inverter, making 
sure the breaker is OFF. Connect the input power to the DC IN terminal blocks using AWG12 
stranded wire. Connect the positive to the RED terminal and the Negative to the BLACK 
terminal.
Tip: For maximum safety, make sure the insulation of the wire butts tightly up to the terminal 
so no un-insulated wire if visible. Trim the length of un-insulated wire if necessary.
CAUTION: Do Not Reverse Connect the Input Wires. This will cause serious Damage to the
Inverter and will not be covered by Warranty.
Turn on the circuit breaker and then press the ON/OFF switch to turn on the inverter. The ON/
OFF switch should illuminate and the Invert LED should come on Green. Once proper operation
is conīrmed, turn the inverter OFF by pressing the ON/OFF switch again.