Product Manual
5
Introduction
All new Current Mode switching design offers increased power and reliability in a compact 
package. Extra input and output ltering reduce EMI to extremely low levels. Reliability 
features include an input fuse, thermal shutdown, current limiting, reverse battery hookup 
protection and output short circuit shutdown with automatic recovery. The output voltage is 
easily adjusted 1.0 volts above or below the standard output voltage to accommodate special 
charging requirements. High quality digital meters can be added (factory option) to allow 
monitoring of output current and output voltage.
Specications
Input Voltages
Nominal (ip) 24 48 72
Actual ** 20 – 35  ** 40 – 60  ** 65 – 90
Input Amps (max) 37.9 19.4 12.1
Input Fuse 3 x ATC15 1 x ATC25 1 x ATC20
Output Voltages
Nominal (op) 12 24 48
Float (Vdc) 13.6 ± 0.05V 27.2 ± 0.05V 54.4 ± 0.05V
Absorption (Vdc) 14.4 28.8 57.6
Charging Amps 40 20 10
Absorption to Float 6.0 Amps 3 Amps 1.5 Amps
Battery Size (Amp Hours)* 160 – 240 80 – 120 40 - 60
Output Adjust ± 1.0 Volts
Output Crowbar 16.0 ± 0.5 V 32 ± 1.0 V 63.9 ± 2.0 V
Equalize Voltage (Vdc) 15.5 31 62
Temperature Compensation 
Coefcient
-30mV / o C -60mV / o C -120mV / o C
Output Fuses ATC-40 x 2 ATC-30 x 2 ATC-15 x 2