Product Manual
6
* This is Analytic Systems’ suggested range. Please consult your battery manufacturer for their recommendations.
* Specications subjects to change without notice.
Installation
MOUNTING
Mount the unit in a DRY location. Allow at least 4 inches of clearance around the heat sink
ns for adequate cooling.
POWER CONNECTION
The unit is supplied with power leads about 3 feet long. This should normally be adequate to
connect to a source of power. If you must extend the power leads, be sure to use at least a
good quality (typeTEW) AWG10 wire. The wire colours are:
Red - Positive
Black - Negative
All connections should be made inside an appropriate junction box. Refer to the specications
table for the correct sizing of the circuit breaker in the distribution panel.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com analyticinfo@analyticsystems.com Revised August 2014
General
Efciency > 80 % @ maximum output
Stages 2 & 3
Temp. Range -25 to +40o C @ maximum output
Isolation
Input-Output & Input-Case 1500 Vdc
Output-Case 500 VDC (1500Vdc @ 48 V Out)
Length 14.5 in / 36.8 cm
Width 9.9 in / 25.1 cm
Height 3.0 in / 7.6 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Black Anodize / Black Powder Epoxy
Fastenings 18-8 Stainless
Weight 7.2 lb / 3.3 kg