Product Manual

6
* Specications subjects to change without notice.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com analyticinfo@analyticsystems.com Revised August 2014
Model BCD600-32-12 BCD600-32-24
Input Volts (DC) 20 - 45 30 - 45
Input Amps 40 40
Output Volts (DC) 13.6 ± 0.5 VDC 27.2 ± 0.5 VDC
Charging Current 50 Amps 38 Amps
Output Crowbar 16.0 ± 0.5 V 32.0 ± 1.0 V
Battery Banks 1
Stages 2
Battery Size (Amp Hours)* 200 - 300 152 - 228
Input Fuses AGC 25 Amp x 2 AGC 25 Amp x 2
Output Fuses AGC 30 Amp x 2 AGC 25 Amp x 2
Transient Response < 1V for 15A Surge
Efciency > 85 % @ maximum output
Temperature Range -25 to +40 deg C @ maximum output
Isolation
Any Input or Output to Case 500VDC
Input to Output common negative
Length 9.1 in / 23.1 cm
Width 7.8 in / 19.8 cm
Height 4.3 in / 10.8 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Black Powder Epoxy
Fastenings 18-8 Stainless
Weight 4.0 lb / 1.8 kg
Specications