The purpose of the Equalize Option is to deliberately overcharge the battery at a low rate of 
current to ensure that all cells are fully charged and to reduce the chance of sulfation. During 
the Equalize cycle, the cells, which are fully charged, will produce Hydrogen gas, and the cells, 
which are undercharged, will be brought up to full charge. An Equalize cycle should be done 
once every 2-3 months, or whenever battery capacity appears to be diminished. The Equal-
ize Option also includes a battery temperature sensor to compensate the charging voltage 
for battery temperature, as well as to shut the charger down if the battery should become 
overheated. A 2nd temperature sensor can be added to allow monitoring of both batteries if 
the charger is connected to 2 banks of batteries. 
An Equalize cycle can be initiated at any time by simply pressing the equalize start button 
located in the hole labeled EQ SEL. This button is deliberately recessed to prevent accidental 
operation. It is most easily pressed by using a ballpoint pen. If the charger is in the middle 
of charging the battery (the Charging LED is on), the Equalize LED will ash. Once the main 
charging cycle is complete, the Equalize cycle will begin and the Equalize LED will stay on all 
the time. If the Charging LED is off when the button is pressed, the Equalize cycle will begin 
immediately. 
Remote Control Option
Equalize Option
A remote control panel may be connected to the inverter using a 9-pin D-connector, which 
attaches to the battery charger. The remote control panel and D connector are part of the 
remote control option. The remote control panel allows the unit to be operated remotely as 
well as duplicating all the diagnostic indicators and audible alarm
REMOTE CONNECTOR
This connector is located on the side of the unit. Important: To prevent the possibility of High 
Voltage Electrical Shock, do not power up the battery charger unless all wiring from the unit to 
the remote is securely connected. Do not remove the dust cover from the DB-9 connector if the 
remote is not being used.
IMPORTANT: This remote is to be used 
only on Battery Chargers manufactured 
by Analytic Systems.