Product Manual
6
* This is Analytic Systems’ suggested range. Please consult your battery manufacturer for their recommendations.
* Specications subjects to change without notice.
Installation
Allow at least 1 inch of clearance all around the case for cooling. The best mounting congu-
ration is to mount the unit on a vertical surface oriented as shown. Use #10 screws of the
appropriate type for the mounting surface to securely mount the unit.
There is 1500 volts of isolation between the input and output, and the input and case. There
is 500 volts of isolation between the output and case. Therefore, the unit may be mounted on
any surface without fear of electrolysis or ground fault.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com analyticinfo@analyticsystems.com Revised August 2014
General
Efciency > 75 % @ maximum output
Stages 2 or 3
Temp. Range -25 to +40o C @ maximum output
Isolation Input-Case & Input-Output 1500 VDC, Output-Case 500 VDC
Length 9.6 in / 24.4 cm
Width 8.2 in / 20.8 cm
Height 3.5 in / 6.4 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Black Powder Epoxy
Fastenings 18-8 Stainless
Weight 7.0 lb / 3.2 kg
INPUT
FUSE
TO
REMOTE
OUTPUT TERMINAL
ON/OFF
INPUT POWER
OUTPUT
FUSE