Product Manual

7
Installation
MOUNTING
Mount the unit in a DRY location. Allow at least 1 inch of clearance for adequate cooling.
POWER CONNECTION
The unit is supplied with input power leads 1 meter long. This should normally be adequate to
connect to a source of power. If you must extend the cable:
•Use the smallest extension length possible.
•Use no less than 10 gauge conductors.
•Splice and solder the joints.
•Protect the joints with heat shrink tubing.
Connect the wires as follows:
•Red to Positive
•Black to Negative
POWER CONNECTION
Two positive output terminals and two negative output terminals are provided. Connect only
one wire to each terminal.
Note that the current specications are for input current. To obtain the maximum output
current capability at any given input voltage, use the following formula:
Output Current = Input Volts / Output Volts x 26
For example:
10 VDC in and 27 VDC out, the max output current = 10/27 x 26 = 9.6 Amps.
20 VDC in and 27 VDC out, the max output current = 20/27 x 26 = 19.3 Amps
It is recommended to parallel the output connections if the unit is used as a single bank battery charger.