Product Manual

6
Specications
Input Voltages
Nominal (ip) 110 220
Actual (Vac) 90 - 130 180 - 260
Frequency (Hz) 45 - 65
Input Amps (max) 5.2 2.6
Input Fuse (slow blow) MDA-7 MDA-4
Output Voltages
Nominal (op) 12 24 32 48
Float (Vdc) 13.6 ± 0.05 27.2 ± 0.05 36.3 ± 0.05 54.4 ± 0.05
Absorption Voltage (Vdc) 14.4 28.8 38.4 57.6
Charging Amps 20 10 7.5 5A
Absorption to Float 3.0 Amps 1.5 Amps 1.13 Amps 0.75A
Battery Banks 1, 2 or 3
Battery Size (Amp Hours)* 80 – 120 40 - 60 30 – 45 20-35
Output Adjust ± 1.0 Volts
Output Fuses AGC 25 AGC 15 AGC 10 AGC10
Output Crowbar 16.0 ± 0.5 V 32.0 ± 1.0 V 42.7 ± 1.3 V 63.5 ± 0.5V
Temperature Compensation Coefcient -30mV / o C -60mV / o C -80mV / o C -120mV / o C
General
Efciency > 75 % @ maximum output
Stages 2 or 3
Temp. Range -40°C to +50°C @ maximum output
Isolation Input-Case & Input-Output 1500 VDC, Output-Case 500 VDC
Length 9.6 in / 24.4 cm
Width 8.2 in / 20.8 cm
Height 3.5 in / 6.4 cm
Clearance 1 Inch (2.5 cm) all around
Material Marine Grade Aluminum
Finish Black Powder Epoxy
Fastenings 18-8 Stainless
Weight 7.0 lb / 3.2 kg
Safety ABS 11-HS794404A-PDA
* Specications subject to change without notice.
* This is Analytic Systems’ suggested range. Please consult your battery manufacturer for their recommendations.