User guide
SMX System MultiMatrix Switcher • SIS Configuration and Control 46
Command ASCII Command
(Host to switcher)
Response
(Switcher to host)
Additional Description
Query system status
S
X2$•X2$•X2$•X2%•X2^•X2^•X3#•X3$]
Query specific system status
nS
X2$ or X2% or X2^ or X3#]
Stsn*X2$ or X2% or X2^ or X3#] Verbose mode 2 or 3
Example:
S
Sts0* 3.31 4.98 24.22 +100.40 03305 03308 1 0
]
3.31 and 4.98 are power supply voltages; 24.22 is fan voltage, 
100.40 (degrees F) is the temperature, 03305 is fan 1 rpm, 
03308 is fan 2 rpm, 1 is primary power supply (OK).
Query switcher information 
(general) per plane (16 actual 
and 10 virtual) plus board 
configuration
I
V
X@
0
XX#
0
AX@
0
XX#
0
•...VX@
15
XX#
15
AX@
15
XX#
15
•...
VX@
25
XX#
25
AX@
25
XX#
25
]
Example:
V16x16A16x16
•V--X--A--X--•V--X--A--X--•V--X--A-
-X--•...
 ...•V--X--A--X--]
NOTE:  The I response gives 26 parameters, the first 16 (V_x_A_x_) is plane information (planes 0-15), and the next 
are virtual planes 1-10 (90-99).
Query model name
Example:
1I
Switcher description (short)
]
Inf01*Switcher description (short)] Verbose mode 2 or 3
Inf01*SMX
]
Query model description
Example:
2I
Switcher description (long)
]
Inf02*Switcher description (long)]  Verbose mode 2 or 3
Inf02*System Multi Matrix
]
Query system-memory usage
3I
# of Bytes used out of # KBytes
]
Inf03*# of Bytes used out of # KBytes Verbose mode 2 or 3
Query user-memory usage
4I
# of Bytes used out of # KBytes
]
Inf04*# of Bytes used out of # KBytes Verbose mode 2 or 3
Query plane address per slot
ESTAT}
X2@
(slot 1)
•X2@
(slot 2)
•...X2@
(
slot 6/8/10)
] Verbose mode 2 and 3
StatX2@
(slot 1)
•X2@
(slot 2)
•...X2@
(slot 6/8/10)
]
Example:
Stat*
5U frame, 10 slots
Slot 1  2   3     4 5 6 7   8 9 10
    00•01•--•02•--•--•03•--•03•03]
Slot 1 00 the board address installed in slot 1 is plane 00
Slot 2 01 the board address installed in slot 2 is plane 01
Slot 3 - - No board installed
NOTES:  X@ = Input number 01 - <maximum number of inputs> 
    00 = untied 
X# = Output number   01 - <maximum number of outputs> 
X2@ = Plane number  00 - 15 
  90 - 99 = virtual plane 
X2$ = Voltage   + or – voltage 
X2% = Temperature 
X2^ = Fan speed   RPM 
X3# = Primary power supply    0 = not installed 
  1 = OK 
  2 = failed 
X3$ = Secondary (redundant) power supply   0 = not installed 
  1 = OK 
    2 = failed