UL Guidelines for Rack Mounted Devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the 
SMX device in a rack.
1.  Elevated operating ambient temperature — If installed in a closed or multi-unit 
rack assembly, the operating ambient temperature of the rack environment may be 
greater than room ambient temperature. Therefore, install the SMX in an environment 
compatible with the maximum ambient temperature (Tma = + 122 ˚F, + 50 ˚C) specified 
by Extron.
2.  Reduced air flow — Install the equipment in a rack so that the amount of air flow 
required for safe operation of the equipment is not compromised.
3.  Mechanical loading — Mount the equipment in the rack so that a hazardous condition 
is not achieved due to uneven mechanical loading.
4.  Circuit overloading — Connect the equipment to the supply circuit and consider the 
effect that circuit overloading might have an overcurrent protection and supply wiring. 
Appropriate consideration of equipment nameplate ratings should be used when 
addressing this concern.
5.  Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted 
equipment. Pay particular attention to supply connections other than direct connections 
to the branch circuit (e.g. use of power strips).
Rack Mounting
To rack mount the SMX, use two screws on each end of the switcher to attach it to the rack 
(see figure 71).
Figure 71. Mounting the SMX
SMX System MultiMatrix Switcher • Reference Information 126