User guide

15
Dimensions: W 482 x D 330 x H 45 mm
19”W x 13,8”D x 1,8”H
Weight: 4,3 kg / 9,5 lbs
(Compatible with a Standard 19” rack, Height = 1 U)
Cooling air ow from right side to left side.
Max ambient operating temperature: < 40°C (< 104°F).
Operating temperature: 0 to +40°C / +32°F to +104°F
Storage temperature: -40 to +70°C / -40°F to +158°F
Operating humidity: 10 to 80% (non condensing)
Input voltage range: 100-240 VAC, 50/60 Hz
Typical consumption: 90 W
CE Compliancy, test following:
- EN 55022: 2006 / A1: 2007,
- EN 55024: 1998 / A1: 2001 / A2: 2003,
- EN 61000-3-2: 2006,
- EN 61000-3-3: 1995 / A1: 2001 / A2: 2005.
Safety, test following:
- IEC 60950-1: 2005,
- UL 60950-1: 2007,
- CAN/CSA-C22.2 NO. 60950-1.
Power supply: IEC/EN/UL/CSA 60950-1, internal, autoswitching
Mechanical (in carton): Vibration: IEC60068-2-64
Free fall: IEC60068-2-32, RoHS, WEEE
Communication specications
Environmental specications
• COMMUNICATION PORTS
REMOTE RS232
Connector: DB 9 female.
Protocol: RS-232.
Data Rate: 9600 Bauds, 8 data bits, 1 stop bit, no parity bit, no ow control
by default.
DTR & RTS needed for upgrade.
• LAN
Connector: RJ45.
Protocol: TCP (Transmission Control Protocol) or UDP
(User Datagram Protocol).
Ethernet: Base 10/100.