User manual

If you need to use your own Software Control program from a
PC or automation, the device allows communication through an
ASCII code protocol. All commands can be found on the CD-Rom
shipped with the Eikos LE in the “External Programming” le.
Information can also be found in the “Progrmmer’s Guide” on
certain media or documentation (website, CD-Rom,...).
All Analog Way products equipped with an RS232 input are
compatible with Crestron, AMX, Medialon, and most major
control systems. TCP/IP control ports are also available on
most Analog Way products, as standard or as options.
To control an Eikos LE product with an External Remote
Controller (PC Software Control - Touch Pad Controller…)
follow the indications below:
1. First establish an RS-232 communication between the
Remote Control Software and the Eikos LE, in order to
setup the LAN parameters of the product.
2. In the “Control” - “Eikos LE LAN Setup” menu, congure
the connection of the Eikos LE product in UDP mode and
setup the Local and Remote Addresses as well as the Local
and Remote Ports in concordance with your Network.
3. Congure the TCP/IP address of your External Remote
Controller.
In example: 192.168.000.001
4. Setup the UDP connection of your External Remote
Controller in concordance with your Network.
In example on the Remote Software in the “Control” -
“RS232/LAN Setup” - “LAN/Setup” menu :
5. Setup the LAN parameters in UDP mode in the “Console”
- “LAN Setup” menu.
In example: RK Address: 192.168.000.002
Remote Address: 192.168.000.010
Gateway Address: 192.168.000.001
RK Port: 10500
Remote Port: 10500
Netmask: 255.255.255.000
6. Select the LAN communication port in the remote controller
console - “RS232/LAN port” menu.
7. You can now control your Eikos LE product with an External
Remote Controller.
7-3. EXTERNAL PROGRAMMING
82