User guide

SETUP DEVICE SYNC CABLE
CHECK DEVICE SYNC OPERATION
FOLLOW SETUP
READY TO OPERATE
Device Sync Device Sync
Complete straight cable (8 wires)
Once all the devices booted and connected to the remote controller, you should setup a show with 3 devices (for
our example) on the same screen. If the device sync function is correctly operated, the 3 devices must show:
For accurate synchronisation, output rate must be set to «framelock» on the same reference for all the devices.
Use Genlock connector or common input as reference.
NB: make sure that other inputs that follows the reference are set «RefSync»
on the input menu (ie. 3 genlocked cameras)
--[DEVICE SYNCHRO]--
Pos: 1 Count: 3
Master
Communication OK
--[DEVICE SYNCHRO]--
Pos: 2 Count: 3
Slave
Communication OK
--[DEVICE SYNCHRO]--
Pos: 3 Count: 3
Slave
Communication OK
Extended
EDID
RefSync
Status
NB: devices will activate device sync functionnality only in multi machine mixer mode (with screen count greater than1).
Devices will not sync if:
- The device sync cable is not connected as above.
- Two or more devices have the same «screen position».
- One of the «Count» devices is missing.
- Version of all devices is not at least v5.00.
80