User guide

If you need to use your own Software Control program from a
PC or automation, the device allows communication through an
ASCII code protocol. All commands can be found on our website:
www.analogway.com/
All Analog Way products equipped with an RS232 input are
compatible with Crestron, AMX, Medialon, and most major control
systems. TCP/IP control ports are also available on most Analog
Way products, as standard or as options.
TIPS:
To control an Di-VentiX II product with an External Remote
Controller (PC Software Control - Touch Pad Controller…) follow
the indications below:
1. First establish a connection between the Remote Control Software
and the Di-VentiX II. Select the RS232/LAN option from the
“Control” menu, and the equivalent in your RCS.
If using RS232 no further setup is required.
2. If using a LAN setup select the TCP / UDP option from the “LAN
setup” menu.
3. Congure the LAN address in your RCS eg 192.168.000.001.
4. Congure the TCP option from the “LAN setup” menu.
Example:
Device address 192.168.0.2
Gateway 192.168.0.1
Device port 10500
Netmask 255.255.255.000
If using a UDP LAN connection you must set up the Remote address
and Remote Port as well.
Once the connection has been setup, you can use your RCS to
control your Di-VentiX II.
7-3. EXTERNAL PROGRAMMING
69