Datasheet
TMP05/TMP06 Data Sheet
Rev. C | Page 12 of 28
140
120
100
80
60
40
20
0
0 10 20 30 40 50 60 70
TIM
E (Seconds)
TEMPERATURE (°C)
TEMPERATURE OF
ENVIRONMENT (30°C)
CHANGED HERE
FINAL TEMPERATURE = 120°C
03340-033
Figure 18. Response to Thermal Shock
1.25
1.00
0.75
0.50
0.25
0
0 5 10 15 20 25 30
LOAD CURRENT (mA)
TEMPERATURE ERROR (°C)
V
DD
= 3.3V AND 5V
AMBIENT TEMPERATURE = 25°C
03340-034
Figure 19. TMP05 Temperature Error vs. Load Current