Inc. SHARC EZ-Extender Manual

System Architecture
2-2 SHARC EZ-Extender Manual
The block diagram in Figure 2-1 shows that each clock and general-pur-
pose signal attached to the analog-to-digital high-speed converter (ADC
HSC) interface is configured depending on how the interface operates.
The EZ-Extender has two clock signals, TX_CLK and RX_CLK. The TX_CLK
signal is used as an output and can be generated in three ways: by applying
a signal via an SMA connector, by using the
RX_CLK signal, or by populat-
Figure 2-1. SHARC EZ-Extender Block Diagram