Datasheet
OP1177/OP2177/OP4177 
Rev. G | Page 20 of 24 
0
2627-065
200Ω
500Ω
4.37kΩ
100Ω
100Ω 20Ω
4.12kΩ
4.12kΩ
5kΩ
49.9kΩ
ADR421
+15
V
0.1µ
F
V+
100Ω
RTD
1/2
OP2177
7
6
5
1/2
OP2177
1
8
2
3
4
V–
V
OU
T
V
OUT
where δ = ∆R/R is the fractional deviation of the RTD resistance 
with respect to the bridge resistance due to the change in temper-
ature at the RTD. 
For δ << 1, the preceding expression becomes 
δ
⎥
⎦
⎤
⎢
⎣
⎡
⎟
⎠
⎞
⎜
⎝
⎛
+
⎟
⎠
⎞
⎜
⎝
⎛
+
⎟
⎠
⎞
⎜
⎝
⎛
=
⎟
⎟
⎟
⎟
⎠
⎞
⎜
⎜
⎜
⎜
⎝
⎛
++
δ
⎟
⎠
⎞
⎜
⎝
⎛
≅
REF
REF
O
V
R2
R1
R2
R1
R
R2
R2
R1
R
R1
V
R
R2
V
 1  
1
With V
REF
 constant, the output voltage is linearly proportional 
to δ with a gain factor of 
⎥
⎦
⎤
⎢
⎣
⎡
⎟
⎠
⎞
⎜
⎝
⎛
+
⎟
⎠
⎞
⎜
⎝
⎛
+
⎟
⎠
⎞
⎜
⎝
⎛
R2
R1
R2
R1
R
R2
V
REF
1  
02627-066
R
R
R
R(1+δ)
ADR421
15V
0.1µ
F
OP1177
6
7
4
2
3
V+
V–
R
F
R
F
V
OUT
Figure 65. Low Power Linearized RTD Circuit 
SINGLE OPERATIONAL AMPLIFIER BRIDGE 
The low input offset voltage drift of the OP1177 makes it very 
effective for bridge amplifier circuits used in RTD signal condi-
tioning. It is often more economical to use a single bridge 
operational amplifier as opposed to an instrumentation amplifier. 
In the circuit shown in Figure 66, the output voltage at the 
operational amplifier is 
Figure 66. Single Bridge Amplifier 
()
⎥
⎥
⎥
⎥
⎦
⎤
⎢
⎢
⎢
⎢
⎣
⎡
⎟
⎟
⎟
⎟
⎠
⎞
⎜
⎜
⎜
⎜
⎝
⎛
δ+
⎟
⎠
⎞
⎜
⎝
⎛
++
δ
=
1 1
R2
R1
R
R1
V
R
R2
V
REF
O