Datasheet
Table Of Contents

OP07
Rev. E | Page 5 of 16
Parameter Symbol Conditions Min Typ Max Unit
OUTPUT CHARACTERISTICS
T
A
= 25°C
Output Voltage Swing V
O
R
L
≥ 10 kΩ ±12.0 ±13.0 V
R
L
≥ 2 kΩ ±11.5 ±12.8 V
R
L
≥ 1 kΩ ±12.0 V
−40°C ≤ T
A
≤ +85°C
Output Voltage Swing V
O
R
L
≥ 2 kΩ ±12 ±12.6 V
DYNAMIC PERFORMANCE
T
A
= 25°C
Slew Rate SR R
L
≥ 2 kΩ
3
0.1 0.3 V/μs
Closed-Loop Bandwidth BW A
VOL
= 1
5
0.4 0.6 MHz
Open-Loop Output Resistance R
O
V
O
= 0, I
O
= 0 60 Ω
Power Consumption P
d
V
S
= ±15 V, No load 80 150 mW
V
S
= ±3 V, No load 4 8 mW
Offset Adjustment Range R
P
= 20 kΩ ±4 mV
1
Input offset voltage measurements are performed by automated test equipment approximately 0.5 seconds after application of power.
2
Long-term input offset voltage stability refers to the averaged trend time of V
OS
vs. the time over extended periods after the first 30 days of operation. Excluding the
initial hour of operation, changes in V
OS
during the first 30 operating days are typically 2.5 μV. Refer to the Typi section. Parameter is
sample tested.
cal Performance Characteristics
3
Sample tested.
4
Guaranteed by design.
5